文章摘要
杨小刚,段洋,冯辉,等.球囊后扩张同时推注对比剂评估支架贴壁的血管内超声评价[J].安徽医药,2020,24(1):61-64.
球囊后扩张同时推注对比剂评估支架贴壁的血管内超声评价
The Intravascular ultrasound evaluation of balloon post?dilatation simultaneous injection contrast evaluating stent adherence
  
DOI:10.3969/j.issn.1009?6469.2020.01.016
中文关键词: 冠心病  球囊扩张术 /方法  冠状血管造影术  超声检查,介入性  顺应性  药物洗脱支架  支架贴壁不良  非顺应性球囊
英文关键词: Coronary disease  Balloon dilation/methods  Coronary angiography  Ultrasonography,interventional  Compliance  Drug?eluting stent  Stent malapposition  Non?compliant balloon
基金项目:
作者单位E-mail
杨小刚 徐州医科大学附属医院心内科江苏徐州 221000  
段洋 徐州医科大学附属医院心内科江苏徐州 221000  
冯辉 徐州医科大学附属医院心内科江苏徐州 221000  
李志 徐州医科大学附属医院心内科江苏徐州 221000  
徐晤 徐州医科大学附属医院心内科江苏徐州 221000 xzxuwu@163.com 
摘要点击次数: 2123
全文下载次数: 574
中文摘要:
      目的采用血管内超声( Intravascular ultrasound,IVUS)评价球囊后扩张同时推注对比剂( Balloon Post?dilatation simulta? neous injection contrast,BPIC)用以判断经皮冠状动脉介入治疗( PCI)时支架的贴壁状态。方法选取 2018年 1月 1日至 2018年 10月 10日,徐州医科大学附属医院行经皮冠状动脉介入治疗术( Percutaneous coronary intervention,PCI)的原位病变冠心病病人 30例。根据定量冠脉造影( Quantitative coronary angiography,QCA)结果指导支架、球囊的选择,在 PCI术中于支架释放后由远及近采用多次 BPIC方法判断支架贴壁,然后行 IVUS检查评价支架释放后的贴壁情况;以 BPIC时球囊远端无前向对比剂且无分支显影时为支架贴壁良好的指标。结果 30例病例,共计植入 54枚支架,经过 BPIC,支架最大直径大于支架型号而与后扩球囊型号相当[(3.54±0.66)比( 3.21±0.55)mm,P<0.05;(3.54±0.66)比( 3.59±0.75)mm,P>0.05],支架对称指数为 0.86±
英文摘要:
      Objective Using Intravascular ultrasound(IVUS)to evaluate the reliability of balloon post?dilatation simultaneous in? jection contrast(BPIC)judging the stent attachment in percutaneous coronary intervention.Methods From January 1,2018 to Oc? tober 10,2018,30 patients with coronary heart disease in situ underwent percutaneous coronary intervention (PCI) in the AffiliatedHospital of Xuzhou Medical University.The results of quantitative coronary angiography(QCA)were used to guide the choice of stent and balloon.In PCI,multiple BPIC were used from far and near to judge the stent attachment after stent release and then theIVUS was used to evaluate the adherence of the stent.When the BPIC was used,no forward contrast agent at the distal end of the balloon and no branch development was used as a good indicator of stent adherence.Results In 30 cases,a total of 54 stents were implanted.After BPIC,the maximum diameter of the stent was larger than that of the stent model and was equivalent to that of the posterior balloon[( 3.54±0.66)vs.(3.21±0.55)mm,P<0.05;(3.54±0.66)vs.(3.59±0.75)mm,P>0.05],the stent symmetry index was 0.86±0.05;there was a significant linear correlation between QCA and IVUS for measuring the maximum diameter of the stent(r=0.997,P=0.000); 50 stents were judged by BPIC and IVUS as good adherence,there was no statistical difference between BPIC and IVUS in judging stent adherence(χ2=2.25,P>0.05).Conclusion The reliability of judging stent attachment by BPICis high and the stent is fully expanded.This method can be used to evaluate stent adherence during PCI.
查看全文   查看/发表评论  下载PDF阅读器
关闭