文章摘要
谢国平,何志忠,李霞.肝细胞癌实时超声造影灌注参数与肿瘤微血管的相关性[J].安徽医药,2020,24(2):366-369.
肝细胞癌实时超声造影灌注参数与肿瘤微血管的相关性
Correlation between real?time contrast?enhanced ultrasound perfusion parameters of hepatocellular carcinoma and tumor microvessel density
  
DOI:10.3969/j.issn.1009?6469.2020.02.040
中文关键词: 癌,肝细胞  超声检查  微血管  实时超声造影  灌注参数
英文关键词: Carcinoma,hepatocellular  Ultrasonography  Microvessels  Real?time contrast?enhanced ultrasound  Perfusion parameters
基金项目:广东省省级科技计划项目( 2013B021800029);东莞市社会科技发展项目( 2018507150011357)
作者单位
谢国平 东莞市人民医院超声科广东东莞 523059 
何志忠 东莞市人民医院超声科广东东莞 523059 
李霞 东莞市人民医院超声科广东东莞 523059 
摘要点击次数: 1681
全文下载次数: 486
中文摘要:
      目的探讨肝细胞癌( HCC)实时超声造影灌注参数与肿瘤微血管( MVD)的相关性。方法选择 2017年 6月至 2018年 10月在东莞市人民医院进行诊治的 40例肝细胞癌病人作为研究对象,术前对所有病人进行实时超声造影检查。造影后定量分析峰值时间增强图像的平均血流密度( MFD)用时间 ?强度曲线( TIC)声学定量分析软件绘制 TIC进行定量分析,得出病灶绝对增强强度( AEI)并对达峰时间( TTP)和峰值强,度( PI)进行记录,将以上记录数据与术后病理免疫组织化学染色计数的微血管密度进行相关性分析。结果 MFD为( 0.78±0.15)、 AEI为( 7.43±3.54)dB、TTP为( 14.24±5.11)s、PI值为( 43.11±10.25)dB。Pearson相关分析显示, MFD、PI与 MVD呈显著正相关( r=0.846;0.732,P=0.013;0.005)TTP值与 MVD呈显著负相关( r= -0.561,P=0.000),AEI与 MVD之间不具备相关性( P>0.05)。结论实时超声造影灌注参数,PI、TTP及 MFD与 MVD的表达具有良好的相关性,可以作为定量评价肿瘤血流生成状况的可靠指标。
英文摘要:
      Objective To investigate the correlation between real?time contrast?enhanced ultrasound perfusion parameters of hepato? cellular carcinoma(HCC) and tumor microvessel density(MVD).Methods Forty patients with hepatocellular carcinoma who were treated in Dongguan People’s Hospital from June 2017 to October 2018 were enrolled in the study.All patients underwent real?time contrast?enhanced ultrasonography before surgery.After angiography,the mean blood flow density(MFD)of the peak time?en? hanced image was quantitatively analyzed with the time?intensity curve(TIC)drawn by TIC acoustic quantitative analysis software to obtain the absolute enhancement of lesions(AEI)and time to progress(TTP)and peak intensity(PI)were recorded.Correlation analysis was made of the above recorded data and the microvessel densityof postoperative pathological immunohistochemical stain?ing.Results The mean MFD,AEI,TTP,and PI of all patients were(0.78±0.15),(7.43±3.54)dB,(14.24±5.11)s,and(43.11±10.25)dB,respectively.Pearson correlation analysis showed that MFD,PI and MVD were significantly positively correlated(r= 0.846;0.732,P=0.013;0.005),TTP value was significantly negatively correlated with MVD(r=-0.561,P=0.000),and there was no correlation between AEI and MVD(P>0.05).Conclusion The real?time contrast?enhanced ultrasound perfusion parame? ters PI,TTP and MFD have a good correlation with the expression of MVD,which can be used as a reliable indicator for quantita? tive evaluation of tumor blood flow.
查看全文   查看/发表评论  下载PDF阅读器
关闭

分享按钮